The kaye validator avs kaye validator avs users manual 2 up to four kaye sensor input modules sims per validator each sim supplies up to 12 thermocouple sensors a kaye high temperature reference htr 400, a kaye low temperature reference ltr 90, ltr 25140 or ltr 40140, or a kaye cold temperature reference. Kaye validator procedure keyword found websites listing. Operating range of 30 to 420c with temp stability of up to 0. Browse and purchase temperature calibrators from whohou marketplace. Instrumentos y equipos del sistema kaye validator 2000. A kaye high temperature reference htr 400, low temperature reference. Htr400 setpoint range 25c above ambient to 400c recommended for calibration of sensors used in steam autoclaves, dry heat ovens and tunnel sterilizers. The kaye validator avs kaye validator avs user s manual 2 up to four kaye sensor input modules sims per validator each sim supplies up to 12 thermocouple sensors a kaye high temperature reference htr 400, a kaye low temperature reference ltr 90, ltr 25140 or ltr 40140, or a kaye cold temperature reference. For sale from kaye instruments htr300 high temperature bath, dry well, used to calibrate temperature sensors etc. The htr 400 is most commonly used with the kaye intelligent rtd irtd probe and. During sensor calibration verifications, sensors are compared against the irtd and offsets are automatically calculated and stored.

European headquarters ge kaye instruments gmbh sinsheimer strasse 6 d75179 pforzheim, germany tel. Combining kayes precision thermal measurement hardware and data. The risk can be detected later through deployed control measuresystem and the detection is through manual. Kaye htr400 50 c to 400 c high temperature reference dry well and other bath dry well furnace calibrators for sale at test equipment center. Kaye htr400 products for sale at test equipment center are thoroughly tested, and receive electrical and cosmetic reconditioning as needed prior to sale.

Avs, valprobe and rf valprobe software for automatic manual calibrations. Ge kaye instruments can be contacted by writing to. Userdefined information entered through the irtd probe software displays in the user label field. A kaye high temperature reference htr400, a kaye low temperature reference ltr140, or a kaye cold temperature reference ctr80. Psc biotech corporation is a strategic partner to life science companies helping fulfill their potential through 3 divisions. B august 2009 august 2009 warranty each instrument manufactured by ge.

Kaye validator avs advanced validation system style. Reference detail operation of kaye validator calibration of measuring. The kaye htr400 dry well employs unique inserts which minimize cooling of the. Standard operating procedure for the kaye validator avs system. Skv lignasweep oscillator kaye instruments htr400 portable drywell temperature calibrator kaye instruments na digistrip iii.

Avsx2015 advanced validation system user manual kaye. A each registrant will specify a unique user name and password and it is solely the responsibility of the registrant to maintain the confidentiality of this user name and password. Kaye validator sisw science instruments and software. Kaye temperature references provide the stable temperature required for sensor calibration. The following definitions apply to the terms warning and caution.

Ohm standard resistor optics positioner laser optics bin 3 unknown optics laser optical bin 3 current calibrator calibrator standard pneumatic calibrator cable for. Enhancements include recall of historical data, live data wiring display, auto sync function and much more. Otherwis e, the protection provided by the instrument may be impaired. Validating the temperature uniformity of your industrial. Intelligent rtd probe used for calibration with ge kaye high. Micro motion sensors and transmitters with enhanced emi immunity comply with emc directive 89336eec and lowvoltage directive 7323eec, when properly installed in. Kaye irtd400 the irtd is a high accuracy traceable temperature standard used as part of the kaye validation systems for calibrating sensors. The kaye validator system is designed to operate with the kaye irtd 400 a selfcontained, highaccuracy temperature standard and a kaye temperature reference ltr90, ltr 40140, ltr 25140, htr 400, ctr 40 or ctr 80. The kaye validator avs offers easy, dedicated and reliable validation. The kaye validator avs advanced validation system combines accurate sensor measurements with all gmp requirements for calibration and traceability to national standards, while generating compliant reports and managing the validated assets and validation equipment. The new flexible cryo logger is designed for easy onsite user verification between studies with the traditional irtd and low temp ctr80 bath or ltr90 dry well.

Jkem scientific temperature monitor temperature controller model cole parmer digisense column heater traceable digital digital temperature controller jkem scientific model temperature indicator yellow springs temptale 4 digisense temperature controller omega engineering i2r thermowatch temperature chart recorder 210 timer globe temperature temp controller wet bulb sensitech. If a ge sensing instrument malfunctions within the warranty period, the following. Combining kaye s precision thermal measurement hardware and data. The kaye product range is relied upon by the worlds leading pharmaceutical and biotechnology companies to validate and monitor critical assets and processes like sterilization as required by governing regulatory bodies. Calibration equipment should only be used by trained personnel. Withnell sensors can complete a ukas accredited calibration on your kaye equipment and we also have kaye equipment for hire. International electrical symbols symbol description ac alternating current acdc battery complies with european union directives dc double insulated. Refer to the safety information in the warnings and cautions sections below. The htr400 with an operating range from 25c above ambient to 400c is ideal for calibrating sensors for autoclaves, dry heat ovens and sterilization tunnels. The new kaye validator avs is a state of the art validation system design that meets industry and regulatory requirements fdagamp for thermal validation.

The ltr 40140 employs unique inserts which minimize cooling of the thermocouple tips due to heat conduction providing an uncertainty of merely 0. The kaye htr 400 high temperature reference provides a stable, portable temperature. One validation console can handle multiple kaye validator avss simultaneously. Advanced validation technology the kaye validator avs advanced validation system is a state of the art validation system design that meets industry and regulatory fda gamp requirements for thermal validation. The ltr 40140 temperature reference is specifically designed to fully automate sensor calibration when used with kaye validation software and traceable temperature standards.

A printer that supports both portrait and landscape page orientation. Durabrand ht400 manuals manuals and user guides for durabrand ht400. Kaye htr400 dry block calibrator for extended high temperature. We have 1 durabrand ht400 manual available for free pdf download. Kaye validator avs advanced validation system wilsonic.

Radiant plasma 4700 plasma spark generator installation guide user manual a s p a r k o f f r e s h a i r contents 1. The validator is a standalone thermal validation system designed to meet new regulations worldwide for validation processes. Aas 920 524e valprobe wireless en 092815 web free download as pdf file. Amounts shown in italicized text are for items listed in currency other than canadian dollars and are approximate conversions to canadian dollars based upon bloombergs conversion rates. Any other user of the instrument may cause unknown hazards to the user. Follow all safety guidelines listed in the users manual. The instrument was designed for temperature calibration. Elite remote flow transmitter, mn rft 9739d430a from the mfg manual. The kaye htr400 dry well employs unique inserts which minimize cooling of the thermocouple tips due to heat conduction, providing an uncertainty of 0. Durabrand ht400 owners manual 27 pages digital home theater audio system. Start the qualification study if start condition is defined as manual.

Kaye validator avs advanced validation system advanced validation system kaye validator avs turn the page to the next generation. Up to four kaye sensor input modules sims per validator each sim supplies up to 12 thermocouple sensors. The htr400 temperature reference is a dry well specifically designed to fully automate sensor calibration when used with kaye validation software and traceable temperature standard. The kaye validator avs system can establish wireless connections by utilizing any kind of available wifi infrastructure like inhouse wifi. The following is specific to the access and usage of hgp websites including and not limited to any and all features and applications.

842 1018 95 1149 1034 1249 1189 136 1220 78 1314 1061 374 1514 1574 1264 1461 528 660 1291 1502 1246 56 1382 96 1141 1167 812 665 321 615 70 811 910 748 660 944 19 1488 894 227 435